Service Test - 151 Fresh Food Door State
• Will show state of Fresh Food Door. OP (open) CL (closed). NOTE: By pushing either fresh food door switches you can toggle from OP (open)
to CL (closed).
Service Test - 152 Freezer Food Door State
• Will show state of Freezer Door. OP (open) CL (closed). NOTE: By pushing freezer door switch you can toggle from OP (open) to CL (closed).
Service Test - 153 Disable Internal Lights
• Press the UR keypad or LR keypad to toggle Enable En and Disable dIS internal lights.
Service Test - 163 Water Dispenser
• Display shows the state of the Water Dispenser Valve (On or OFF). NOTE: By pushing Actuator pad or Express Fill keypad you can control Water
Dispenser Valve.
Service Test - 164 External Ice Chute Door
• Display shows the state of the External Ice Chute Door CL (closed) or OP (open). NOTE: By pushing Actuator pad you can control state of
External Ice Chute Door.
Service Test - 165 Dispenser Lamp
• Display shows the state of the Dispenser Lamp (On or OFF). NOTE: By pushing Actuator or Express Fill keypad you can control dispenser lamp.
Service Test - 167 Cavity Heater Test (On some models)
• Toggles the state of the Cavity Heater On or OFF. NOTE: Pushing UR or LR keypads toggles the cavity heaters state to On or OFF
Service Test - 168 Cube Dispenser and Internal Ice Chute Door Operation
• Display shows the state of the ice auger motor and the internal ice chute door. (On or OFF) NOTE: By pushing actuator pad you can control
state of the Ice auger motor and the internal ice chute door.
Service Test - 171 Actuator Pad
• Display shows the state of the Actuator Pad (On or OFF).
Service Test - 172 Front Fill (On some models)
• Display shows the state of the Front Fill (On or OFF).
Service Test - 173 Ambient Light
• Display shows light sensor measurement (Hi or Lo). Night light will turn on when light sensor measures Lo. By changing the
sensor's exposure to ambient light you can control the sensor measurement.
Service Test - 175 Dispenser Switch
• Display shows the state of the Dispenser Switch (On or OFF). NOTE: By pushing Actuator pad or Express Fill keypad you can change state of
Dispenser Switch.
Service Test - 182 LED Indicator Operation
• Press the UR or LR keypads to show operation of LED Indicators. All LED’s will flash. Press again and LED will stop flashing.
Service Test - 183 Keypad Operation
• Display shows a numeric or letter display indicating the last key pressed. NOTE: UR and LR keypads have no effect when pressed and UL and LL
keypads remain operational.
Service Test - 192 Ice Maker State Test
• Display shows dr if left fresh food door switch is in the door open position.
• Display shows OFF if ice maker power switch is in the off position and door closed.
• Display shows On if the ice maker power switch is in the on position and the door closed and heater is off.
• Display shows OnH if icemaker power switch is in the on position and harvest heater is on and door closed.
Service Test - 193 Ice Maker Relay
• Press the UR Keypad or LR Keypad to toggle the ice maker relay On and OFF.
*NOTE: Service tests 201-213 modify factory settings to suit customer's needs.
Service Test - 201 Mullion Heater Override
• Press the UR or LR Keypad to change Mullion Heater from cycling on with compressor (OFF position) to 100% operation (On position). NOTE: If
present, the Humidity Control Button toggles between the selected Mullion Heater Function and 0% operation.
Service Test - 202 Default Defrost Operation
• Press the UR or LR Keypad to change Defrost Operation from normal adaptive defrost (Off position) to minimum time between defrosts (On
position).
Service Test - 203 Show Temp Set points - Disregard this Test - Unit will not display actual temp only set temp.
Service Test - 211 Fresh Food Temperature Adjustment
• Press the UR or LR Keypad to change calibration of Fresh Food Temperature plus or minus in 1°F increments up to 6°F.
Service Test - 212 Freezer Temperature Adjustment
• Press the UR or LR Keypad to change calibration of Freezer Temperature plus or minus 1°F in increments up to 6°F.
Service Test - 213 Ice Compartment Temperature Adjustment
• Press the UR or LR Keypad to change calibration of Ice Maker Compartment Temperature + or - 1°F in increments up to + 8°F.
Service Test - 221 Reset Default Settings
• Press the UR or LR Keypad to reset to factory default settings dEF.
Service Test - 231 Water Filter Usage
• Display shows the percent water filter consumption since water filter was reset. 100% indicates the filter should be replaced.
Service Test - 232 Water Filter Days In Use
• Display shows the number of days since the water filter was reset.
Service Test - 241 Software Revision Main Control Board
• Display shows the Software revision of the Main Control Board.
Service Test - 244 Software Revision Display Board
• Display shows the Software revision of the Display Board.
NOTE: Service tests 3XX and above are Reserved for Engineering Use Only.